Zennio KNX Actuators
35 models
MAXinBOX — multichannel actuators
(8)MINiBOX — compact (2 DIN)
(4)
ZIOMN20V2
MINiBOX 20 v2 — KNX multifunction actuator with KNX Secure, 2 outputs 16A
2 outputs: one shutter channel or 2 individual loads

ZIOMN25V3
MINiBOX 25 v3 — KNX multifunction actuator with KNX Secure, 2 outputs 16A / 5 inputs A/D
2 outputs (one shutter channel or 2 loads), 5 analogue/digital inputs, 4 thermostats

ZIOMN40V3
MINiBOX 40 v3 — KNX multifunction actuator with KNX Secure, 4 outputs 16A
4 outputs: up to 2 shutter channels, 4 loads or one 2-pipe fan coil

ZIOMN45V3
MINiBOX 45 v3 — Fan coil controller with KNX Secure for 2-pipe unit / 5 inputs A/D
4 outputs (shutters, loads, fan coil), plus 5 analogue/digital inputs and 4 thermostats
MicroBOX — 1 DIN
(2)inBOX — for back boxes
(2)Shutter actuators and DC motor adaptors
(8)
ZAC-SHUC1C
AC/DC Shutter coupler for one channel
230 VAC control input → a 12–24 VDC motor up to 8 A; needs a separate 12–24 VDC supply

ZAC-SHUC2C
AC/DC Shutter coupler for up to two channels
Two 230 VAC inputs → two 12–24 VDC motors, 8 A per channel; needs a 12–24 VDC supply

ZIOMBSH4V3
MAXinBOX SHUTTER 4CH v3 — Shutter actuator with KNX Secure 4 channels
Travel times set by parameter, no current-based measurement; 4.5 DIN units

ZIOMBSH8V3
MAXinBOX SHUTTER 8CH v3 — Shutter actuator with KNX Secure 8 channels
Travel times set by parameter, no current-based measurement; 8 DIN units

ZIOSHD2
ShutterBOX Drive 2CH — 2-channel shutter actuator with automatic travel time detection
Measures travel times from motor current (AC motors); 2 DIN units

ZIOSHD4
ShutterBOX Drive 4CH — 4-channel shutter actuator with automatic travel time detection
Measures travel times from motor current (AC motors); 4 DIN units

ZIOSHD6
ShutterBOX Drive 6CH — 6-channel shutter actuator with automatic travel time detection
Measures travel times from motor current (AC motors); 6 DIN units

ZIOSHD8
ShutterBOX Drive 8CH — 8-channel shutter actuator with automatic travel time detection
Measures travel times from motor current (AC motors); 8 DIN units
ALLinBOX — all-in-one
(3)IndustrialBOX — 20 A power relays
(4)IndustrialBOX Current — with current metering
(4)Mounting and accessories (12)Back boxes, terminals, adaptors, licences and spare parts of this section. They are not cards of the grid — each has its own page.
- 9900024IR Remote controller for ALLinBOX
- ZACCOMBCable comb for up to 8 cables
- ZACMB8CBComb busbar for MAXinBOX 8, Upper and lower comb
- ZACMB66CBComb busbar for MAXinBOX 66, Lower comb
- ZACMB12CBComb busbar for MAXinBOX 12, Upper and lower comb
- ZACMB16CBComb busbar for MAXinBOX 16, MAXinBOX Shutter 8CH, Upper and lower comb
- ZACMB20CBComb busbar for MAXinBOX 20, Upper and lower comb
- ZACMB24CBComb busbar for MAXinBOX 24, Upper and lower comb
- ZACAB1612CBComb busbar for ALLinBOX 1612 v3, Upper and lower comb
- ZACPCCBComb busbar, Protector plastic cap, 12 units
- ZACMB1212CBComb busbar for MAXinBOX 1212, Upper and lower comb
- ZACMB88CBComb busbar for MAXinBOX 88, Upper and lower comb
ZENNIO Actuators: section overview
This section includes 35 models of Zennio actuators. The DIN-rail MAXinBOX line spans models from 6 to 24 relay outputs at 16 A, including the combined MAXinBOX 66 v3, 88 and 1212 with analogue/digital inputs; for blinds there are MAXinBOX SHUTTER 4CH/8CH v3 with 8 A outputs and ShutterBOX Drive with 2–8 channels. The compact MINiBOX 20/25/40/45 provide 2–4 outputs at 16 A and up to 5 A/D inputs, MicroBOX 12 and 22 take 1 DIN unit, and inBOX 20/24 v3 (Ø 51.4 mm) fit distribution boxes or wall back boxes. For industrial loads there are IndustrialBOX 2/4/8/12 with 20 A outputs and capacitive loads up to 200 µF, plus Current versions that measure the current of each output. ALLinBOX 46/88/1612 combine an actuator, a KNX power supply and a KNX-IP interface. Most actuators support KNX Secure. Comb busbars, cable combs and the IR remote for manual output control of ALLinBOX are in the “Mounting and accessories” list under the grid.
Frequently asked questions
How do I choose an actuator by channel count?
Count the controlled circuits (lighting, socket groups, blind drives) and add a reserve: MAXinBOX with 6–24 outputs suits the distribution board, and MINiBOX with 2–4 outputs or the 1-DIN-unit MicroBOX suits small nodes. For a distribution box or wall back box there are the 2-output inBOX 20/24 v3, Ø 51.4 × 26.6 mm; different phases must not be connected to them.
What do the A/D inputs in actuators provide?
They accept conventional switches, push buttons, contacts and temperature probes — the signals reach the KNX bus without separate input modules. A/D inputs are found, for example, on MINiBOX 25/45 (5 inputs), MAXinBOX 66 v3, 88 and 1212 (6, 8 and 12 inputs) and MicroBOX 12/22 (2 inputs).
How to buy Zennio KNX actuators in Kazakhstan?
We are the official Zennio distributor in Kazakhstan and deliver equipment nationwide; it carries the manufacturer's warranty. Request a quote via the contact page or the specification configurator on this site.